Lung Ultrasound Induction of Pulmonary Capillary Hemorrhage in Neonatal Swine

      Abstract

      This study investigated induction of pulmonary capillary hemorrhage (PCH) in neonatal pigs (piglets) using three different machines: a GE Venue R1 point-of-care system with C1-5 and L4-12t probes, a GE Vivid 7 Dimension with a 7L probe and a SuperSonic Imagine machine with an SL15-4 probe and shear wave elastography (SWE). Female piglets were anesthetized, and each was mounted vertically in a warm bath for scanning at two or three intercostal spaces. After aiming at an innocuous output, the power was raised for a test exposure. Hydrophone measurements were used to calculate in situ values of mechanical index (MIIS). Inflated lungs were removed and scored for PCH area. For the C1-5 probe at 50% and 100% acoustical output (AO), a PCH threshold of 0.53 MIIS was obtained by linear regression (r2 = 0.42). The L4-12t probe did not induce PCH, but the 7L probe induced zones of PCH in the scan planes. The Venue R1 automated B-line tool applied with the C1-5 probe did not detect PCH induced by the C1-5 probe as B-line counts. However, when PCH induced by C1-5 and 7L exposures were subsequently scanned with the L4-12t probe using the automated tool, B-lines were counted in association with the PCH. The SWE induced PCH at push-pulse positions for 3, 30 and 300 s of SWE with PCH accumulating at 0.33 mm2/s and an exponential rise to a maximum of 18.4 mm2 (r2 = 0.61). This study demonstrated the induction of PCH by LUS of piglets, and supports the safety recommendation for use of MIs <0.4 in neonatal LUS.

      Key Words

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Ultrasound in Medicine and Biology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Ahmad S
        • Eisen LA.
        Lung ultrasound: The basics.
        in: Lumb P Karakitsos D Critical care ultrasound. Elsevier, Philadelphia2015: 106-110
        • American Institute of Ultrasound in Medicine (AIUM)
        Statement on mammalian biological effects in tissues with naturally occurring gas bodies.
        Author, Laurel, MD2015
        • Baggs R
        • Penney DP
        • Cox C
        • Child SZ
        • Raeman CH
        • Dalecki D
        • Carstensen EL.
        Thresholds for ultrasonically induced lung hemorrhage in neonatal swine.
        Ultrasound Med Biol. 1996; 22: 119-128
        • Baloescu C
        • Toporek G
        • Kim S
        • McNamara K
        • Liu R
        • Shaw MM
        • McNamara RL
        • Raju BI
        • Moore CL.
        Automated lung ultrasound B-Line assessment using a deep learning algorithm.
        IEEE Trans Ultrason Ferroelectr Freq Control. 2020; 67: 2312-2320
        • Brattain LJ
        • Telfer BA
        • Liteplo AS
        • Noble VE.
        Automated B-line scoring on thoracic sonography.
        J Ultrasound Med. 2013; 32: 2185-2190
        • British Medical Ultrasound Society (BMUS)
        Guidance document on ultrasound safety issues when scanning a neonate.
        Physics and Safety Committee of the BMUS, London2021
        • Brusasco C
        • Santori G
        • Bruzzo E
        • Trò R
        • Robba C
        • Tavazzi G
        • Guarracino F
        • Forfori F
        • Boccacci P
        • Corradi F.
        Quantitative lung ultrasonography: A putative new algorithm for automatic detection and quantification of B-lines.
        Crit Care. 2019; 23: 288
        • Chen SW
        • Fu W
        • Liu J
        • Wang Y.
        Routine application of lung ultrasonography in the neonatal intensive care unit.
        Medicine (Baltimore). 2017; 96: e5826
        • Child SZ
        • Hart man CL
        • Schery LA
        • Carstensen EL.
        Lung damage from exposure to pulsed ultrasound.
        Ultrasound Med Biol. 1990; 16: 817-825
        • Church CC
        • Carstensen EL
        • Nyborg WL
        • Carson PL
        • Frizzell LA
        • Bailey MR.
        The risk of exposure to diagnostic ultrasound in postnatal subjects: Nonthermal mechanisms.
        J Ultrasound Med. 2008; 27: 565-592
        • Copetti R
        • Cattarossi L
        • Macagno F
        • Violino M
        • Furlan R.
        Lung ultrasound in respiratory distress syndrome: a useful tool for early diagnosis.
        Neonatology. 2008; 94: 52-59
        • Corsini I
        • Parri N
        • Ficial B
        • Dani C.
        Lung ultrasound in the neonatal intensive care unit: Review of the literature and future perspectives.
        Pediatr Pulmonol. 2020; 55: 1550-1562
        • Dalecki D
        • Child SZ
        • Raeman CH
        • Cox C
        • Carstensen EL.
        Ultrasonically induced lung hemorrhage in young swine.
        Ultrasound Med Biol. 1997; 23: 777-781
        • De Martino L
        • Yousef N
        • Ben-Ammar R
        • Raimondi F
        • Shankar-Aguilera S
        • De Luca D.
        Lung ultrasound score predicts surfactant need in extremely preterm neonates.
        Pediatrics. 2018; 142e20180463
        • Dietrich CF
        • Mathis G
        • Blaivas M
        • Volpicelli G
        • Seibel A
        • Wastl D
        • Atkinson NS
        • Cui XW
        • Fan M
        • Yi D.
        Lung B-line artefacts and their use.
        J Thorac Dis. 2016; 8: 1356-1365
        • Dietrich CF
        • Buda N
        • Ciuca IM
        • Dong Y
        • Fang C
        • Feldkamp A
        • Jüngert J
        • Kosiak W
        • Mentzel HJ
        • Pienar C
        • Rabat JS
        • Rafailidis V
        • Schrading S
        • Schreiber-Dietrich D
        • Jaworska J.
        Lung ultrasound in children, WFUMB review paper (part 2).
        Med Ultrason. 2021; 23: 443-452
        • Gunes AO
        • Karadag N
        • Cakir H
        • Toptan HH
        • Karatekin G.
        The associations between lung ultrasonography scores in the first day of life and clinical outcomes.
        J Ultrasound Med. 2022; 41: 417-425
        • Jagła M
        • Krzeczek O
        • Buczyńska A
        • Zakrzewska Z
        • Kwinta P.
        The safety of pulmonary ultrasonography in the neonatal intensive care unit.
        Dev Period Med. 2018; 22: 75-80
        • Kurepa D
        • Zaghloul N
        • Watkins L
        • Liu J.
        J Neonatal lung ultrasound exam guidelines.
        Perinatol. 2018; 38: 11-22
        • Lichtenstein DA
        • Mauriat P.
        Lung ultrasound in the critically ill neonate.
        Curr Pediatr Rev. 2012; 8: 217-223
        • Lichtenstein D
        • Mézière G
        • Biderman P
        • Gepner A
        • Barré O.
        The comet-tail artifact. An ultrasound sign of alveolar–interstitial syndrome.
        Am J Respir Crit Care Med. 1997; 156: 1640-1646
        • Liu J
        • Chi JH
        • Ren XL
        • Li J
        • Chen YJ
        • Lu ZL
        • Liu Y
        • Fu W
        • Xia RM.
        Lung ultrasonography to diagnose pneumothorax of the newborn.
        Am J Emerg Med. 2017; 35: 1298-1302
        • Liu J
        • Copetti R
        • Sorantin E
        • Lovrenski J
        • Rodriguez-Fanjul J
        • Kurepa D
        • Feng X
        • Cattaross L
        • Zhang H
        • Hwang M
        • Yeh TF
        • Lipener Y
        • Lodha A
        • Wang JQ
        • Cao HY
        • Hu CB
        • Lyu GR
        • Qiu XR
        • Jia LQ
        • Wang XM
        • Ren XL
        • Guo JY
        • Gao YQ
        • Li JJ
        • Liu Y
        • Fu W
        • Wang Y
        • Lu ZL
        • Wang HW
        • Shang LL.
        Protocol and guidelines for point-of-care lung ultrasound in diagnosing neonatal pulmonary diseases based on international expert consensus.
        J Vis Exp. 2019; : 145
        • Liu Y
        • Zhen Y
        • Zhang X
        • Gao F
        • Lu X.
        Application of transthoracic shear wave elastography in evaluating subpleural pulmonary lesions.
        Eur J Radiol Open. 2021; 8100364
        • Matthias I
        • Panebianco NL
        • Maltenfort MG
        • Dean AJ
        • Baston C.
        Effect of machine settings on ultrasound assessment of B-lines.
        J Ultrasound Med. 2020; 40: 2039-2046
      1. Miller RJ, Frizzell LA, Zachary JF, O'Brien WD Jr. Attenuation coefficient and propagation speed estimates of intercostal tissue as a function of pig age. IEEE Trans Ultrason Ferroelectr Freq Control. 2002;49:1421–9.

        • Miller DL.
        Induction of pulmonary hemorrhage in rats during diagnostic ultrasound.
        Ultrasound Med Biol. 2012; 38: 1476-1482
        • Miller DL
        • Dou C
        • Raghavendran K.
        The dependence of thresholds for pulmonary capillary hemorrhage on diagnostic ultrasound frequency.
        Ultrasound Med Biol. 2015; 41: 1640-1650
        • Miller DL
        • Dou C
        • Raghavendran K.
        Anesthetic techniques influence the induction of pulmonary capillary hemorrhage during diagnostic ultrasound in rats.
        J Ultras Med. 2015; 34: 289-297
      2. Miller DL. Mechanisms for Induction of Pulmonary Capillary Hemorrhage by Diagnostic Ultrasound: Review and Consideration of Acoustical Radiation Surface Pressure. Ultrasound Med Biol. 2016;42:2743–2757.

        • Miller DL
        • Dong Z
        • Dou C
        • Raghavendran K.
        Influence of scan duration on pulmonary capillary hemorrhage induced by diagnostic ultrasound.
        Ultrasound Med Biol. 2016; 42: 1942-1950
        • Miller DL
        • Dou C
        • Dong Z
        • Raghavendran K.
        The influence of dexmedetomidine on ultrasound-induced pulmonary capillary hemorrhage in rats.
        Ultrasound Med Biol. 2016; 42: 964-970
        • Miller DL
        • Dong Z
        • Dou C
        • Raghavendran K.
        Pulmonary capillary hemorrhage induced by different imaging modes of diagnostic ultrasound.
        Ultrasound Med Biol. 2018; 44: 1012-1021
        • Miller DL
        • Dong Z
        • Dou C
        • Raghavendran K.
        Does intravenous infusion influence diagnostic ultrasound-induced pulmonary capillary hemorrhage?.
        J Ultrasound Med. 2018; 37: 2021-2028
        • Miller DL
        • Dong Z
        • Dou C
        • Raghavendran K.
        Pulmonary capillary hemorrhage induced by diagnostic ultrasound in ventilated rats.
        Ultrasound Med Biol. 2018; 44: 1810-1817
        • Miller DL
        • Dong Z
        • Dou C
        • Patterson B
        • Raghavendran K.
        Pulmonary capillary hemorrhage induced by supersonic shear wave elastography in rats.
        Ultrasound Med Biol. 2019; 45: 2993-3004
        • Miller DL
        • Dou C
        • Raghavendran K
        • Dong Z.
        Variation of diagnostic ultrasound-induced pulmonary capillary hemorrhage with fraction of inspired oxygen.
        Ultrasound Med Biol. 2020; 46: 1978-1985
        • Miller DL
        • Abo A
        • Abramowicz JS
        • Bigelow TA
        • Dalecki D
        • Dickman E
        • Donlon J
        • Harris G
        • Nomura J.
        Diagnostic ultrasound safety review for point-of-care ultrasound practitioners.
        J Ultrasound Med. 2020; 39: 1069-1084
        • Miller DL
        • Dou C
        • Raghavendran K
        • Dong Z.
        The influence of xylazine and clonidine on lung ultrasound-induced pulmonary capillary hemorrhage in spontaneously hypertensive rats.
        Ultrasound Med Biol. 2021; 47: 2331-2338
        • Mongodi S
        • De Luca D
        • Colombo A
        • Stella A
        • Santangelo E
        • Corradi F
        • Gargani L
        • Rovida S
        • Volpicelli G
        • Bouhemad B
        • Mojoli F.
        Quantitative lung ultrasound: Technical aspects and clinical applications.
        Anesthesiology. 2021; 134: 949-965
        • O'Brien Jr, WD
        • Simpson DG
        • Ho MH
        • Miller RJ
        • Frizzell LA
        • Zachary JF
        Superthreshold behavior and threshold estimation of ultrasound-induced lung hemorrhage in pigs: Role of age dependency.
        IEEE Trans Ultrason Ferroelectr Freq Control. 2003; 50: 153-169
        • Oktem A
        • Yigit S
        • Oğuz B
        • Celik T
        • Haliloğlu M
        • Yurdakok M.
        Accuracy of lung ultrasonography in the diagnosis of respiratory distress syndrome in newborns.
        J Matern Fetal Neonatal Med. 2019; 34: 281-286
      3. Patterson B, Miller DL. Experimental Measurements of Ultrasound Attenuation in Human Chest Wall and Assessment of the Mechanical Index for Lung Ultrasound. Ultrasound Med Biol. 2020;46:1442–1454.

        • Raimondi F
        • Migliaro F
        • Corsini I
        • Meneghin F
        • Dolce P
        • Pierri L
        • Perri A
        • Aversa S
        • Nobile S
        • Lama S
        • Varano S
        • Savoia M
        • Gatto S
        • Leonardi V
        • Capasso L
        • Carnielli VP
        • Mosca F
        • Dani C
        • Vento G
        • Lista G
        Lung ultrasound score progress in neonatal respiratory distress syndrome.
        Pediatrics. 2021; 147e2020030528
        • Razak A
        • Faden M.
        Neonatal lung ultrasonography to evaluate need for surfactant or mechanical ventilation: A systematic review and meta-analysis.
        Arch Dis Child Fetal Neonatal Ed. 2020; 105: 164-171
        • Richards JR
        • Awrey JM
        • Medeiros SE
        • McGahan JP.
        Color and power Doppler sonography for pneumothorax detection.
        J Ultrasound Med. 2017; 36: 2143-2147
        • Sande R
        • Jenderka KV
        • Moran CM
        • Marques S
        • JF Jimenez Diaz
        • G Ter Haar
        • Marsal K
        • Lees C
        • Abramowicz JS
        • KÅ Salvesen
        • Miloro P
        • Dall'Asta A
        • Brezinka C
        • Kollmann C
        Safety aspects of perinatal ultrasound.
        Ultraschall Med. 2021; 42: 580-598
        • Sartori S
        • Tombesi P.
        Emerging roles for transthoracic ultrasonography in pleuropulmonary pathology.
        World J Radiol. 2010; 2: 83-90
        • Short J
        • Acebes C
        • Rodriguez-de-Lema G
        • La Paglia GMC
        • Pavón M
        • Sánchez-Pernaute O
        • Vazquez JC
        • Romero-Bueno F
        • Garrido J
        • Naredo E
        Visual versus automatic ultrasound scoring of lung B-lines: Reliability and consistency between systems.
        Med Ultrason. 2019; 21: 45-49
        • Singh Y
        • Tissot C
        • Fraga MV
        • Yousef N
        • Cortes RG
        • Lopez J
        • Sanchez-de-Toledo J
        • Brierley J
        • Colunga JM
        • Raffaj D
        • Da Cruz E
        • Durand P
        • Kenderessy P
        • Lang HJ
        • Nishisaki A
        • Kneyber MC
        • Tissieres P
        • Conlon TW
        • De Luca D
        International evidence-based guidelines on point of care ultrasound (POCUS) for critically ill neonates and children issued by the POCUS Working Group of the European Society of Paediatric and Neonatal Intensive Care (ESPNIC).
        Crit Care. 2020; 24: 65
        • Soldati G
        • Demi M
        • Smargiassi A
        • Inchingolo R
        • Demi L.
        The role of ultrasound lung artifacts in the diagnosis of respiratory diseases.
        Expert Rev Respir Med. 2019; 13: 163-172
        • Soldati G
        • Smargiassi A
        • Inchingolo R
        • Buonsenso D
        • Perrone T
        • Briganti DF
        • Perlini S
        • Torri E
        • Mariani A
        • Mossolani EE
        • Tursi F
        • Mento F
        • Demi L
        Proposal for international standardization of the use of lung ultrasound for patients with COVID-19: A simple, quantitative, reproducible method.
        J Ultrasound Med. 2020; 39: 1413-1419
        • Spengler D
        • Rintz N
        • Krause MF.
        An unsettled promise: The newborn piglet model of neonatal acute respiratory distress syndrome (NARDS): Physiologic data and systematic review.
        Front Physiol. 2019; 10: 1345
        • Sweet DG
        • Carnielli V
        • Greisen G
        • Hallman M
        • Ozek E
        • Te Pas A
        • Plavka R
        • Roehr CC
        • Saugstad OD
        • Simeoni U
        • Speer CP
        • Vento M
        • Visser GHA
        • Halliday HL
        European consensus guidelines on the management of respiratory distress syndrome—2019 update.
        Neonatology. 2019; 115: 432-450
        • Wu Y
        • Kharge AB
        • Perlman CE.
        Lung ventilation injures areas with discrete alveolar flooding, in a surface tension-dependent fashion.
        J Appl Physiol (1985). 2014; 117: 788-796
        • Zhou B
        • Bartholmai BJ
        • Kalra S
        • Osborn TG
        • Zhang X.
        Lung US surface wave elastography in interstitial lung disease staging.
        Radiology. 2019; 291: 479-484
      4. Zhou B, Yang X, Zhang X, Curran WJ, Liu T. Ultrasound Elastography for Lung Disease Assessment. IEEE Trans Ultrason Ferroelectr Freq Control. 2020;67:2249–2257.