High Frame Rate Contrast-Enhanced Ultrasound Imaging for Slow Lymphatic Flow: Influence of Ultrasound Pressure and Flow Rate on Bubble Disruption and Image Persistence

      Abstract

      Contrast-enhanced ultrasound (CEUS) utilising microbubbles shows great potential for visualising lymphatic vessels and identifying sentinel lymph nodes (SLNs) which are valuable for axillary staging in breast cancer patients. However, current CEUS imaging techniques have limitations that affect the accurate visualisation and tracking of lymphatic vessels and SLN. (i) Tissue artefacts and bubble disruption can reduce the image contrast. (ii) Limited spatial and temporal resolution diminishes the amount of information that can be captured by CEUS. (iii) The slow lymph flow makes Doppler-based approaches less effective. This work evaluates on a lymphatic vessel phantom the use of high frame rate (HFR) CEUS for the detection of lymphatic vessels where flow is slow. Specifically, the work particularly investigates the impact of key factors in lymphatic imaging, including ultrasound pressure and flow velocity as well as probe motion during vessel tracking, on bubble disruption and image contrast. Experiments were also conducted to apply HFR CEUS imaging on vasculature in a rabbit popliteal lymph node (LN). Our results show that (i) HFR imaging and singular value decomposition (SVD) filtering can significantly reduce tissue artefacts in the phantom at high clinical frequencies; (ii) the slow flow rate within the phantom makes image contrast and signal persistence more susceptible to changes in ultrasound amplitude or mechanical index (MI), and an MI value can be chosen to reach a compromise between images contrast and bubble disruption under slow flow condition; (iii) probe motion significantly decreases image contrast of the vessel, which can be improved by applying motion correction before SVD filtering; (iv) the optical observation of the impact of ultrasound pressure on HFR CEUS further confirms the importance of optimising ultrasound amplitude and (v) vessels inside rabbit LN with blood flow less than 3 mm/s are clearly visualised.

      Key Words

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Ultrasound in Medicine and Biology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Baranger J
        • Arnal B
        • Perren F
        • Baud O
        • Tanter M
        • Demené C
        Adaptive spatiotemporal SVD clutter filtering for ultrafast Doppler imaging using similarity of spatial singular vectors.
        IEEE Trans Med Imaging. 2018; 37: 1574-1586
        • Bentel GC
        • Marks LB
        • Hardenbergh PH
        • Prosnitz LR
        Variability of the depth of supraclavicular and axillary lymph nodes in patients with breast cancer: Is a posterior axillary boost field necessary?.
        Int J Radiat Oncol Biol Phys. 2000; 47: 755-758
      1. Brock-Fisher G, Poland M, Rafter P. Means for increasing sensitivity in non-linear ultrasound imaging systems. Patent: US 5577505; 1996. Available at: https://patents.google.com/patent/US5577505A/en. Accessed 26 November 2018.

        • Couture O
        • Fink M
        • Tanter M
        Ultrasound contrast plane wave imaging.
        IEEE Trans Ultrason Ferroelectr Freq Control. 2012; 59: 2676-2683
        • Cox K
        • Sever A
        • Jones S
        • Weeks J
        • Mills P
        • Devalia H
        • Fish D
        • Jones P
        Validation of a technique using microbubbles and contrast enhanced ultrasound (CEUS) to biopsy sentinel lymph nodes (SLN) in pre-operative breast cancer patients with a normal grey-scale axillary ultrasound.
        Eur J Surg Oncol EJSO. 2013; 39: 760-765
        • de Jong N
        • Emmer M
        • van Wamel A
        • Versluis M
        Ultrasonic characterization of ultrasound contrast agents.
        Med Biol Eng Comput. 2009; 47: 861-873
        • Demené C
        • Deffieux T
        • Pernot M
        • Osmanski BF
        • Biran V
        • Gennisson JL
        • Sieu LA
        • Bergel A
        • Franqui S
        • Correas JM
        • Cohen I
        • Baud O
        • Tanter M
        Spatiotemporal clutter filtering of ultrafast ultrasound data highly increases Doppler and ultrasound sensitivity.
        IEEE Trans Med Imaging. 2015; 34: 2271-2285
        • Demené C
        • Tiran E
        • Sieu L-A
        • Bergel A
        • Gennisson JL
        • Pernot M
        • Deffieux T
        • Cohen I
        • Tanter M
        4 D microvascular imaging based on ultrafast Doppler tomography.
        NeuroImage. 2016; 127: 472-483
        • Denarie B
        • Tangen TA
        • Ekroll IK
        • Rolim N
        • Torp H
        • Bjåstad T
        • Lovstakken L
        Coherent plane wave compounding for very high frame rate ultrasonography of rapidly moving targets.
        IEEE Trans Med Imaging. 2013; 32: 1265-1276
        • Desailly Y
        • Tissier A-M
        • Correas J-M
        • Wintzenrieth F
        • Tanter M
        • Olivier Couture
        Contrast enhanced ultrasound by real-time spatiotemporal filtering of ultrafast images.
        Phys Med Biol. 2017; 62: 31
        • Freitas Jr, RA
        Nanomedicine, volume I: Basic capabilities.
        CRC Press, Boca Raton, FL1999 (Available at:)
        • Fujishima M
        • Watatani M
        • Inui H
        • Hashimoto Y
        • Yamamoto N
        • Hojo T
        • Hirai K
        • Yamato M
        • Shiozaki H
        Touch imprint cytology with cytokeratin immunostaining versus Papanicolau staining for intraoperative evaluation of sentinel lymph node metastasis in clinically node-negative breast cancer.
        Eur J Surg Oncol EJSO. 2009; 35: 398-402
        • Garbin V
        • Cojoc D
        • Ferrari E
        • Di Fabrizio E
        • Overvelde MLJ
        • van der Meer SM
        • de Jong N
        • Lohse D
        • Versluis M
        Changes in microbubble dynamics near a boundary revealed by combined optical micromanipulation and high-speed imaging.
        Appl Phys Lett. 2007; 90114103
        • Goldberg BB
        • Merton DA
        • Liu J-B
        • Thakur M
        • Murphy GF
        • Needleman L
        • Tornes A
        • Forsberg F
        Sentinel lymph nodes in a swine model with melanoma: Contrast-enhanced lymphatic US.
        Radiology. 2004; 230: 727-734
        • Harput S
        • Christensen-Jeffries K
        • Brown J
        • Li Y
        • Williams KJ
        • Davies AH
        • Eckersley RJ
        • Dunsby C
        • Tang M-X
        Two-Stage Motion Correction for Super-Resolution Ultrasound Imaging in Human Lower Limb.
        IEEE Trans Ultrason Ferroelectr Freq Control. 2018; 65: 803-814
        • Lin S
        • Zhang G
        • Leow CH
        • Tang M-X
        Effects of microchannel confinement on acoustic vaporisation of ultrasound phase change contrast agents.
        Phys Med Biol. 2017; 62: 6884
        • Madsen EL
        • Frank GR
        • Dong F
        Liquid or solid ultrasonically tissue-mimicking materials with very low scatter.
        Ultrasound Med Biol. 1998; 24: 535-542
        • Montaldo G
        • Tanter M
        • Bercoff J
        • Benech N
        • Fink M
        Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography.
        IEEE Trans Ultrason Ferroelectr Freq Control. 2009; 56: 489-506
        • Pan W-R
        • le Roux CM
        • Levy SM
        • Briggs CA
        The morphology of the human lymphatic vessels in the head and neck.
        Clin Anat. 2010; 23: 654-661
        • Pesek S
        • Ashikaga T
        • Krag LE
        • Krag D
        The false-negative rate of sentinel node biopsy in patients with breast cancer: A meta-analysis.
        World J Surg. 2012; 36: 2239-2251
        • Postema M
        • Bouakaz A
        • Chin CT
        • Jong N de
        Optically observed microbubble coalescence and collapse.
        2002 IEEE Ultrason Symp 2002 Proc. 2002; 2: 1949-1952
        • Postema M
        • Marmottant P
        • Lancée CT
        • Hilgenfeldt S
        • Jong N de
        Ultrasound-induced microbubble coalescence.
        Ultrasound Med Biol. 2004; 30: 1337-1344
        • Postema M
        • van Wamel A
        • Lancée CT
        • de Jong N
        Ultrasound-induced encapsulated microbubble phenomena.
        Ultrasound Med Biol. 2004; 30: 827-840
        • Sever AR
        • Mills P
        • Jones SE
        • Cox K
        • Weeks J
        • Fish D
        • Jones PA
        Preoperative sentinel node identification with ultrasound using microbubbles in patients with breast cancer.
        AJR Am J Roentgenol. 2011; 196: 251-256
        • Simpson DH
        • Chin CT
        • Burns PN
        Pulse inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents.
        IEEE Trans Ultrason Ferroelectr Freq Control. 1999; 46: 372-382
        • Somasundaram SK
        • Chicken DW
        • Keshtgar MRS
        Detection of the sentinel lymph node in breast cancer.
        Br Med Bull. 2007; 84: 117-131
        • Song P
        • Manduca A
        • Trzasko JD
        • Chen S
        Ultrasound small vessel imaging with block-wise adaptive local clutter filtering.
        IEEE Trans Med Imaging. 2017; 36: 251-262
        • Tang M-X
        • Kamiyama N
        • Eckersley RJ
        Effects of nonlinear propagation in ultrasound contrast agent imaging.
        Ultrasound Med Biol. 2010; 36: 459-466
        • Tanter M
        • Fink M.
        Ultrafast imaging in biomedical ultrasound.
        IEEE Trans Ultrason Ferroelectr Freq Control. 2014; 61: 102-119
        • Temple LKF
        • Baron R
        • Cody HS
        • Fey JV
        • Thaler HT
        • Borgen PI
        • Heerdt AS
        • Montgomery LL
        • Petrek JA
        • Van Zee KJ
        Sensory morbidity after sentinel lymph node biopsy and axillary dissection: A prospective study of 233 women.
        Ann Surg Oncol. 2002; 9: 654-662
        • van der Ven M
        • Luime JJ
        • van der Velden LL
        • Bosch JG
        • Hazes JMW
        • Vos HJ
        High-frame-rate power Doppler ultrasound is more sensitive than conventional power Doppler in detecting rheumatic vascularisation.
        Ultrasound Med Biol. 2017; 43: 1868-1879
        • Veronesi U
        • Paganelli G
        • Viale G
        • Luini A
        • Luini S
        • Galimberti V
        • Intra M
        • Veronesi P
        • Robertson C
        • Maisonneuve P
        • Renne G
        • De Cicco C
        • De Lucia F
        • Gennari R
        A Randomized comparison of sentinel-node biopsy with routine axillary dissection in breast cancer.
        N Engl J Med. 2003; 349: 546-553
        • Wong J
        • Yong WS
        • Thike AA
        • Iqbal J
        • Salahuddin AS
        • Ho GH
        • Madhukumar P
        • Tan BKT
        • Ong KW
        • Tan PH
        False negative rate for intraoperative sentinel lymph node frozen section in patients with breast cancer: A retrospective analysis of patients in a single Asian institution.
        J Clin Pathol. 2015; 68: 536-540
        • Zheng H
        • Dayton PA
        • Caskey C
        • Zhao S
        • Qin S
        • Ferrara KW
        Ultrasound-driven microbubble oscillation and translation within small phantom vessels.
        Ultrasound Med Biol. 2007; 33: 1978-1987
        • Zhu J
        • Rowland EM
        • Harput S
        • Riemer K
        • Leow CH
        • Clark B
        • Cox K
        • Lim A
        • Christensen-Jeffries K
        • Zhang G
        • Brown J
        • Dunsby C
        • Eckersley RJ
        • Weinberg PD
        • Tang M-X
        3D super-resolution ultrasound imaging of rabbit lymph node vasculature in vivo using microbubbles.
        Radiology. 2019; 291: 642-650