An Analysis of the Origin of Differences between Measured and Simulated Fields Produced by A 15-Element Ultrasound Phased Array

  • Adam H. Aitkenhead

      Affiliations

    • Department of Physics, The University of Warwick, Coventry, UK
    • Corresponding Author InformationAddress correspondence to: Adam H. Aitkenhead, North Western Medical Physics, The Christie NHS Foundation Trust, Manchester, U.K.
  • ,
  • John A. Mills

      Affiliations

    • Department of Radiotherapy Physics, University Hospitals Coventry and Warwickshire, Coventry, UK
  • ,
  • Adrian J. Wilson

      Affiliations

    • Department of Physics, The University of Warwick, Coventry, UK
    • Department of Radiotherapy Physics, University Hospitals Coventry and Warwickshire, Coventry, UK

Received 3 September 2009; received in revised form 18 November 2009; accepted 24 November 2009. published online 04 February 2010.

Abstract 

Modeling provides an attractive approach for the design of phased array ultrasound transducers for hyperthermia. However, measurements on physical transducers reveal differences from the idealized field profiles predicted by simulation. In this paper we report a method of analyzing the origins of these differences. The measured performance of a 15-element sparse phased array is described and compared with simulated fields calculated using the point source method. It highlighted two notable differences: First, that the focal region was located closer to the surface of the physical transducer than in the simulated fields; and second, that numerous intensity maxima were present between the surface of the transducer and the focal zone in the experimental data, but not in the simulated fields. We identified six factors that could potentially affect the field but were not taken into account by the default simulations, and we performed a sensitivity analysis on these: (i) Variation in the amplitude of the output from each element, (ii) the presence of square-wave harmonics in the drive signals, (iii) nonpistonlike vibration of elements, (iv) quantization of the applied phases, (v) errors in the spatial positioning of each element; and (vi) interelement cross-coupling. Both the independent impact of each factor and the interactions between multiple factors were analyzed by using a full-factorial experimental design composed of 64 (26) simulations. The results indicated that nonpistonlike motion of elements is likely to be the primary cause of differences between the measured and modelled fields. Determination of the precise vibrational modes of elements in an array is complex and would require full finite element analysis. However, the simple vibrational mode considered within the present work, corresponding to the addition of a surface Rayleigh wave originating at the element center and propagating radially, produced simulation results that were in good agreement with the measured data. (E-mail: adam.aitkenhead@physics.cr.man.ac.uk)

Key Words: Hyperthermia, Ultrasound, Phased array, Sensitivity analysis

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(09)01658-5

doi:10.1016/j.ultrasmedbio.2009.11.010

Ultrasound in Medicine and Biology
Volume 36, Issue 3 , Pages 410-418, March 2010