Transthoracic Ultrasonography in Predicting the Outcome of Small-Bore Catheter Drainage in Empyemas or Complicated Parapneumonic Effusions

Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan

Received 10 September 2008; received in revised form 20 April 2009; accepted 22 April 2009. published online 21 July 2009.

Abstract 

Thoracic sonography has been advocated as being complementary to small-bore catheter drainage in pleural effusions. However, it is not known whether the initial sonographic appearances of empyemas or complicated parapneumonic effusions (CPPEs) can predict the outcomes of small-bore catheter drainage for these pleural insults. This retrospective study investigated the outcomes of patients who had been diagnosed with empyema and CPPE and had received ultrasound-guided small-bore catheter (size from 12F to 16F) drainage in a tertiary university hospital from September 2005 to August 2007. Patients were excluded when empyemas or CPPEs were traumatic, they were less than 18 years old or their charts were incomplete. We evaluated 141 small-bore catheters in 70 patients with empyemas and 71 patients with CPPEs over a two-year period. The mean age was 58±15 y and the male gender was more frequent (112 men, 79%). The overall successful rate of small-bore catheter drainage in empyemas or CPPEs was 63% (89/141). The sonographic appearances of these empyemas or CPPEs exhibited a complex septated pattern in 57% (81/141) of patients and a complex nonseptated pattern in 43% (60/141) of patients. The success rate in a complex nonseptated sonographic pattern was significantly higher than in a complex septated sonographic pattern (48/60, 80% vs. 41/81, 51%, respectively; p=0.001). Moreover, patients with complex septated sonographic patterns also had higher intensive care unit admission rates compared with nonseptated sonographic patterns (22/81, 27%, vs. 8/60, 13%, respectively; p=0.0047), as well as infection-related mortality rates (17/81, 21% vs. 4/60, 7%, respectively; p=0.018). The appearance of sonographic septation is a useful sign to help predict the outcome of small-bore catheter drainage in cases of empyemas or CPPEs. Patients with a complex septated sonographic pattern have a poorer prognosis for a successful outcome, higher ICU admission rate and a higher mortality rate.

Key Words: Empyema, Complicated parapneumonic effusion, Chest sonography, Small-bore catheter

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(09)00205-1

doi:10.1016/j.ultrasmedbio.2009.04.021

Ultrasound in Medicine and Biology
Volume 35, Issue 9 , Pages 1468-1474, September 2009