Ultrasound in Medicine and Biology
Volume 35, Issue 8 , Pages 1352-1366, August 2009

Effects of Various Parameters on Lateral Displacement Estimation in Ultrasound Elastography

  • Jianwen Luo

      Affiliations

    • Ultrasound and Elasticity Imaging Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
  • ,
  • Elisa E. Konofagou

      Affiliations

    • Ultrasound and Elasticity Imaging Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
    • Department of Radiology, Columbia University, New York, NY, USA
    • Corresponding Author InformationAddress correspondence to: Elisa E. Konofagou, Ph.D., Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, mail code 8904, 1210 Amsterdam Avenue, New York, NY 10027.

Received 8 September 2008; received in revised form 18 February 2009; accepted 3 March 2009. published online 15 June 2009.

Abstract 

Complementary to axial, lateral displacement and strain can provide important information on the biological soft tissues. In this paper, the effects of key parameters (i.e., lateral displacement, pitch, beamwidth, beam overlap and interpolation) on lateral displacement estimation were investigated, in simulations and homogeneous phantom experiments, using lateral rigid motion only to study its fundamentals separately from the effects of axial motion and 2-D deformation on lateral displacement estimation. The performance of the lateral motion estimator was evaluated by measuring its associated bias, jitter and correlation coefficient. Simulation results showed that the bias and jitter of the lateral displacement estimation and correlation coefficient of RF signals undergo periodic variations depending on the lateral displacement, with a period equal to the pitch. The performance of the lateral estimation was improved when a smaller pitch or a larger beamwidth, was used. The effect of the pitch on the lateral estimation on lateral displacement estimation was found to be greater than the beamwidth effect. Therefore, a smaller pitch is preferred when the beam overlap remains the same. The use of cubic spline, instead of linear interpolation, increases the correlation coefficient, and decreases the jitter, with the trade-off of increased bias. The results of the phantom experiments were shown in good agreement with the simulation findings, including the periodic variation of the performance with lateral displacement and effects of pitch, beamwidth and interpolation method on lateral displacement estimation. In conclusion, smaller pitch, wider beamwidth and spline interpolation were shown to be key in reducing the jitter error in the lateral displacement estimation. (E-mail: ek2191@columbia.edu)

Key Words: Beam overlap, Beamwidth, Bias, Correlation Coefficient, Cross-correlation, Displacement, Elastography, Estimation, Imaging, Interpolation, Jitter, Lateral Displacement, Motion, Performance, Pitch, Radiofrequency (RF) signal, Spline, Strain

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(09)00101-X

doi:10.1016/j.ultrasmedbio.2009.03.001

Ultrasound in Medicine and Biology
Volume 35, Issue 8 , Pages 1352-1366, August 2009