Ultrasound in Medicine and Biology
Volume 35, Issue 8 , Pages 1325-1343, August 2009

Reduction of Echo Decorrelation via Complex Principal Component Filtering

  • F. William Mauldin Jr.

      Affiliations

    • Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
    • Corresponding Author InformationAddress correspondence to: F. William Mauldin, Jr., Department of Biomedical Engineering, University of Virginia, Box 800759, Health System, Charlottesville, VA 22908.
  • ,
  • Francesco Viola

      Affiliations

    • Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
  • ,
  • William F. Walker

      Affiliations

    • Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
    • Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, USA

Received 11 July 2008; received in revised form 6 November 2008; accepted 31 January 2009. published online 11 June 2009.

Abstract 

Ultrasound motion estimation is a fundamental component of clinical and research techniques that include color flow Doppler, spectral Doppler, radiation force imaging and ultrasound-based elasticity estimation. In each of these applications, motion estimates are corrupted by signal decorrelation that originates from nonuniform target motion across the acoustic beam. In this article, complex principal component filtering (PCF) is demonstrated as a filtering technique for dramatically reducing echo decorrelation in blood flow estimation and radiation force imaging. We present simulation results from a wide range of imaging conditions that illustrate a dramatic improvement over simple bandpass filtering in terms of overall echo decorrelation (≤99.9% reduction), root mean square error (≤97.3% reduction) and the standard deviation of displacement estimates (≤97.4% reduction). A radiation force imaging technique, termed sonorheometry, was applied to fresh whole blood during coagulation, and complex PCF operated on the returning echoes. Sonorheometry was specifically chosen as an example radiation force imaging technique in which echo decorrelation corrupts motion estimation. At 2 min after initiation of blood coagulation, the average echo correlation for sonorheometry improved from 0.996 to 0.9999, which corresponded to a 41.0% reduction in motion estimation variance as predicted by the Cramer-Rao lower bound under reasonable imaging conditions. We also applied complex PCF to improve blood velocity estimates from the left carotid artery of a healthy 23-year-old male. At the location of peak blood velocity, complex PCF improved the correlation of consecutive echo signals from an average correlation of 0.94 to 0.998. The improved echo correlation for both sonorheometry and blood flow estimation yielded motion estimates that exhibited more consistent responses with less noise. Complex PCF reduces speckle decorrelation and improves the performance of ultrasonic motion estimation. (E-mail: fwm5f@virginia.edu)

Key Words: Acoustic radiation force imaging, Blood velocity estimation, Complex principal component filtering, Motion estimation, Time delay estimation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(09)00054-4

doi:10.1016/j.ultrasmedbio.2009.01.013

Ultrasound in Medicine and Biology
Volume 35, Issue 8 , Pages 1325-1343, August 2009