Quantification of Muscle Volume by Echography: Comparison with MRI Data on Subjects in Long-Term Bed Rest

  • Philippe Arbeille

      Affiliations

    • UMPS-Unité de Médecine et Physiologie Spatiales, Départment Médecine Nucléaire et Ultrasons, CHU Trousseau, Tours, France
    • Corresponding Author InformationAddress correspondence to: Pr Philippe Arbeille, Med Nucl Ultrasons, CHU Trousseau, 37044 – Tours, France.
  • ,
  • Pascaline Kerbeci

      Affiliations

    • UMPS-Unité de Médecine et Physiologie Spatiales, Départment Médecine Nucléaire et Ultrasons, CHU Trousseau, Tours, France
  • ,
  • Arnaud Capri

      Affiliations

    • UMPS-Unité de Médecine et Physiologie Spatiales, Départment Médecine Nucléaire et Ultrasons, CHU Trousseau, Tours, France
  • ,
  • Charles Dannaud

      Affiliations

    • UMPS-Unité de Médecine et Physiologie Spatiales, Départment Médecine Nucléaire et Ultrasons, CHU Trousseau, Tours, France
  • ,
  • Scott W. Trappe

      Affiliations

    • Human Performance Laboratory, Ball State University, Muncie, IN, USA
  • ,
  • Todd A. Trappe

      Affiliations

    • Human Performance Laboratory, Ball State University, Muncie, IN, USA

Received 28 January 2008; received in revised form 23 December 2008; accepted 9 January 2009. published online 27 April 2009.

Abstract 

The objective of this study was to determine the accuracy of an echographic method for measuring the change in leg muscle volume against the gold standard, magnetic resonance imaging (MRI). Leg muscle volume was measured using an echographic scanner, which consisted of two metallic rails on which a probe holder moved via an electric engine. Ten to 20 transverse muscle views were collected along the area scanned, and the muscle cross-sectional area (CSA, cm2) was measured on each of them. The integration of all the CSAs along the scanned area provided the muscle volume (cm3). Echographic results were compared with MRI data on 24 subjects undergoing 60 d of bed rest (8 control “Con,” 8 with exercise countermeasures “Ex” and 8 with nutrition countermeasures “Nut”). The vastus intermedius (VI) and the vastus medialis (VM) volumes decreased significantly and similarly in both Con and Nut (VI, –17%; VM, –21%; p < 0.02). In the Ex group, the VI and VM did not change significantly. The correlation coefficient between the muscle volume change measured with the echographic and MRI methods was 0.78. The present study confirms that the echographic scanner is sufficiently accurate for assessing muscle volume changes and detects the effect of exercise countermeasures on muscle volume during long-term bed rest. (E-mail: arbeille@med.univ-tours.fr)

Key Words: Muscle, Atrophy, Echography, MRI, Bed rest

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(09)00024-6

doi:10.1016/j.ultrasmedbio.2009.01.004

Ultrasound in Medicine and Biology
Volume 35, Issue 7 , Pages 1092-1097, July 2009