Ultrasound in Medicine and Biology
Volume 34, Issue 11 , Pages 1732-1740, November 2008

Quantitative Analysis of Echocardiographic Cine-Loops Using a 2D-Strain Algorithm in Correlation with Thallium-201 SPECT Imaging

  • Aaron Miller

      Affiliations

    • The Abramson Center of Medical Physics, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel
    • Corresponding Author InformationAddress correspondence to: Aaron Miller, Abramson Center for Medical Physics, School of Physics and Astronomy, Tel-Aviv University, Tel-Aviv 69978, Israel
  • ,
  • Pierre Chouraqui

      Affiliations

    • Heart Institute, Sheba Medical Center, Tel Hashomer, Israel
  • ,
  • Gil Zwirn

      Affiliations

    • The Abramson Center of Medical Physics, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel
  • ,
  • Micha S. Feinberg

      Affiliations

    • Heart Institute, Sheba Medical Center, Tel Hashomer, Israel
  • ,
  • Solange Akselrod

      Affiliations

    • The Abramson Center of Medical Physics, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel

Received 25 July 2007; received in revised form 19 February 2008; accepted 24 March 2008. published online 11 August 2008.

Abstract 

The aim of this study was to investigate the correlation between the regional left ventricular (LV) contractility, assessed by two-dimensional (2D)-strain echocardiographic images, and regional LV perfusion, determined by thallium-201 single photon emission computed tomography (SPECT) imaging. Forty-five hospitalized patients with suspected myocardial ischemia (32 males, mean age 69 ± 12 years) have undergone both echocardiography and SPECT imaging on the same day. The echocardiographic data has been obtained in three apical views. The data for each view has been processed by the 2D-strain algorithm, to produce six peak systolic longitudinal strain measurements per view, one per segment. The resulting measurements have been compared with the corresponding regions within the SPECT bull's-eye map (at rest). In order to handle inaccuracies in the positioning of the echocardiographic transducer, the two datasets have undergone registration based on local correlation. The mean correlation coefficients between SPECT perfusion and peak systolic longitudinal strain for the apical long-axis, apical two-chamber, and apical four-chamber views were 0.55 ± 0.36, 0.47 ± 0.35, and 0.64 ± 0.30 respectively (negative correlation coefficients have been considered as zero). The overall mean correlation coefficient was 0.56 ± 0.34. The scatter graphs of the average values of perfusion and the strain values showed a nonlinear relation between the two parameters. The average correlation coefficient is comparable to the values reported for the correlation between the average LV function, based on visual analysis of echocardiographic imaging, and the average LV perfusion, based on SPECT imaging. (E-mail: aaronisme@yahoo.com)

Key Words: Echocardiography, SPECT imaging, Two-dimensional (2D) strain, Multi-modal registration

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(08)00184-1

doi:10.1016/j.ultrasmedbio.2008.03.021

Ultrasound in Medicine and Biology
Volume 34, Issue 11 , Pages 1732-1740, November 2008