Evaluation of a Novel Solid-State Method for Determining the Acoustic Power Generated by Physiotherapy Ultrasound Transducers

  • Bajram Zeqiri

      Affiliations

    • Corresponding Author InformationAddress correspondence to: Dr Bajram Zeqiri, Acoustics Group, Quality of Life Division, National Physical Laboratory, Teddington, Middlesex, TW11 0LW United Kingdom
  • ,
  • Jill Barrie

Acoustics Group, Quality of Life Division, National Physical Laboratory, Teddington, United Kingdom

Received 24 August 2007; received in revised form 23 January 2008; accepted 4 February 2008. published online 28 April 2008.

Abstract

A new secondary method of determining ultrasound power is presented based on the pyroelectricity of a thin membrane of the piezoelectric polymer, polyvinylidene fluoride (PVDF). In operation, the membrane is backed by a polyurethane-based rubber material that is extremely attenuating to ultrasound, resulting in the majority of the acoustic power applied to the PVDF being absorbed within a short distance of the membrane-backing interface. The resulting rapid heating leads to a pyroelectric voltage being generated across the electrodes of the sensor that, under appropriate conditions, is related to the rate of change of temperature with respect to time. For times immediately after changes in transducer excitation (switching either ON or OFF), the change in the pyroelectric voltage is proportional to the delivered ultrasound power level. This paper describes a systematic evaluation of the measurement concept applied at physiotherapy frequencies and power levels, investigating key aspects such as repeatability, linearity and sensitivity. The research demonstrates the way that heating of the backing material affects the sensor performance, but outlines the potential of the method as a reproducible, rapid, solid-state method of determining power, requiring calibration using a known ultrasound power source. (E-mail: bajram.zeqiri@npl.co.uk)

Key Words: Ultrasonic power measurement, Physiotherapy transducers, Pyroelectric method, Polyvinylidene fluoride, Thermal technique

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(08)00073-2

doi:10.1016/j.ultrasmedbio.2008.02.003

Ultrasound in Medicine and Biology
Volume 34, Issue 9 , Pages 1513-1527, September 2008