Ultrasound in Medicine and Biology
Volume 34, Issue 3 , Pages 414-424 , March 2008

Noninvasive Estimation of Temperature Elevations in Biological Tissues Using Acoustic Nonlinearity Parameter Imaging

Received 11 October 2006 ,Revised 24 August 2007 ,Accepted 5 September 2007.

References 

  1. Arthur RM, Straube WL, Starman JD, Moros EG. Noninvasive temperature estimation based on the energy of backscattered ultrasound. Med Phys. 2003;30:1021–1029
  2. Arthur RM, Straube WL, Trobaugh JW, Moros EG. Noninvasive estimation of hyperthermia temperatures with ultrasound. Int J Hyperthermia. 2005;21:589–600
  3. Beyer RT. Parameter of nonlinearity in fluids. J Acoust Soc Am. 1960;32:719–721
  4. Beyer RT. Nonlinear acoustics. In: Washington: DC Naval Sea Systems Command, US Dept. of the Navy; 1974;p. 91–101
  5. Bjørnø L. Characterization of biological media by means of their non-linearity. Ultrasonics. 1986;4:254–259
  6. Cain C. Ultrasonic reflection mode imaging of the nonlinearity parameter B/A: A theoretical basis. J Acoust Soc Am. 1986;80:28–32
  7. Carter D, MacFall J, Clegg S, Wan X, Prescott D, Charles H, et al. Magnetic resonance thermometry during hyperthermia for human high-grade sarcoma. Int J Radiat Oncol Biol Phys. 1998;40:815–822
  8. Coppens AB, Beyer RT, Seiden MB, Donohue J, Guepin F, Hodon RH, et al. Parameter of nonlinearity in fluids II. J Acoust Soc Am. 1965;38:797–804
  9. Curra FP, Mourad PD, Khokhlova VA, Cleveland RO, Crum LA. Numerical simulations of heating patterns and tissue temperature response due to high-intensity focused ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control. 2000;47:1077–1089
  10. Damianou CA, Sanghvi NT, Fry FJ, MaassMoreno R. Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose. J Acoust Soc Am. 1997;102:628–634
  11. Dewhirst MW, Prosnitz L, Thrall D, Prescott D, Cleff S, Charles C, et al. Hyperthermic treatment of malignant diseases: Current status and a view toward the future. Semin Oncol. 1997;24:616–625
  12. Gellermann J, Wlodarczyk W, Ganter H, Nadobny J, Fahling H, Seebass M, et al. A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system: Validation in a heterogeneous phantom. Int J Radiat Oncol Biol Phys. 2005;61:267–277
  13. Gertner MR, Wilson BC, Sherar MD. Ultrasound properties of liver tissue during heating. Ultrasound Med Biol. 1997;23:1395–1403
  14. Gong XF, Feng R, Zhu ZY. Ultrasonic investigation of the nonlinearity parameter B/A in biological media. J Acoust Soc Am. 1984;76:949–950
  15. Gong XF, Zhu ZM, Shi T, Huang JH. Determination of the acoustic nonlinearity parameter in biological media using FAIS and ITD method. J Acoust Soc Am. 1989;86:1–5
  16. Gong XF, Liu XZ, Zhang D. Influence of tissue composition and structural features of biological media in the ultrasonic nonlinearity parameter. Chinese J Acoust. 1993;12:265–270
  17. Gong XF, Zhang D, Liu JH, Wang HL, Yan YS, Xu XC. Study on acoustic nonlinearity parameter imaging for biological tissues in reflection mode. J Acoust Soc Am. 2004;116:1819–1825
  18. Hill CR. Calibration of ultrasonic beams for biomedical applications. Phys Med Biol. 1970;15:241–248
  19. In:  Hill CR,  Bamber JC,  Ter Haar GR editor. Attenuation and absorption (Physical principles of medical ultrasonics). London: John Wiley & Sons; 2004;p. 93–992nd
  20. Holmes KR. Biological Structures and Heat Transfer. In: The Future of Biothermal Engineering. Allerton, IL: Allerton Workshop, University of Illinois; 1997;p. 14–37April 18–21
  21. Hynynen K, Chung A, Fjield T, Buchanan M, Daum D, Colucci V, et al. Feasibility of using ultrasound phased arrays for MRI monitored noninvasive surgery. IEEE Trans Ultrason Ferroelectr Freq Control. 1996;43:1043–1053
  22. Ichida N, Sato T, Linzer M. Imaging the nonlinear ultrasonic parameter of a medium. Ultrason Imaging. 1983;5:295–299
  23. Ichida N, Sato T, Miwa H, Murakami K. Real-time nonlinear parameter tomography using impulsive pumping waves. IEEE Trans Sonics Ultrason SU-31. 1984;6:635–641
  24. Krishnan P, Yang TH, Lee WY, Kim CS. PtRu-LiCoO2-an efficient catalyst for hydrogen generation from sodium borohydride solutions. Journal of Power Sources. 2005;143:17–23
  25. Law WK, Frizzell LA, Dunn F. Determination of the nonlinearity parameter B/A of biological media. Ultrasound Med Biol. 1985;11:307–317
  26. Li YD, Chen Q, Zagzbski J. Harmonic ultrasonic fields through layered liquid media. IEEE Trans Ultrason Ferroelectr Freq Control. 2004;51:146–152
  27. Lu Y, Liu XZ, Gong XF, Zhang D. The relationship between the temperature and the acoustic nonlinearity parameter in biological tissues. Chinese Science Bulletin. 2004;49:2360–2363
  28. Lucas BG, Muir TG. Field of finite-amplitude focusing source. J Acoust Soc Am. 1983;74:1522–1528
  29. MaassMoreno R, Damianou CA. Noninvasive temperature estimation in tissue via ultrasound echo-shifts Part I: Analytical model. J Acoust Soc Am. 1996;100:2514–2521
  30. MaassMoreno R, Damianou CA, Sanghvi NT. Noninvasive temperature estimation in tissue via ultrasound echo-shifts Part II: In vitro study. J Acoust Soc Am. 1996;100:2522–2530
  31. Meaney P, Paulsen K, Hartov A, Crane R. Microwave imaging for tissue assessment: Initial evaluation in multitarget tissue-equivalent phantoms. IEEE Trans Biomed Eng. 1996;43:878–890
  32. Miller NR, Bamber JC, ter Harr GR. Imaging of temperature-induced echo strain: Preliminary in vitro study to assess feasibility for guiding focused ultrasound surgery. Ultrasound Med Biol. 2004;30:345–356
  33. Muir TG, Carstensen EL. Prediction of nonlinear acoustic effects of biological frequencies and intensities. Ultrasound Med Biol. 1980;6:345–357
  34. Myerson RJ, Moros E, RotiRoti JL. Hyperthermia. In:  Perez CA,  Brady LW editor. Principles and practice of radiation oncology. 3d edition. Philadelphia: Lippincott-Raven; 1998;p. 637–683
  35. Nadobny J, Wlodarczyk W, Westhoff L, Gellermann J, Felix RR, Wust P. A clinical water-coated antenna applicator for MR-controlled deep-body hyperthermia: A comparison of calculated and measured 3-D temperature data sets. IEEE Trans Biomed Eng. 2005;52:505–519
  36. Nakagawa Y, Hou W, Cai A, Arnold N, Wade G. Nonlinear parameter imaging with finite-amplitude sound waves. Ultrason Symp. 1986;901–904
  37. Paulsen K, Moskowitz M, Ryan T, Mitchell S, Hoopes P. Initial in vivo experience with EIT as a thermal estimator during hyperthermia. Int J Hyperthermia. 1996;12:573–591
  38. Pennes HH. Analysis of tissue and arterial blood temperatures in the resting human forearm. J Appl Physiol. 1948;1:93–122
  39. Phillips RA, Van Slyke DD, Hamilton PB, Dole VP, Emerson K, Archibald RM. Measurement of specific gravities of whole blood and plasma by standard copper sulfate solution. J Biol Chem. 1950;183:305–330
  40. Pinkerton JMM. The absorption of ultrasonic waves in liquids and its relation to molecular constitution. Proc Phys Soc. 1949;B62:129–147
  41. Prakash O, Fabbri M, Drocourt M, Escanye JM, Marchal C, Gaulard ML, et al. Hyperthermia induction and its measurement using ultrasound. Proc IEEE Symp Ultrason. 1980;1063–1106
  42. Sehgal CM, Brown GM, Bahn RC, Greenleaf JF. Measurement and use of acoustic nonlinearity and sound speed to estimate composition of excised livers. Ultrasound Med Biol. 1986;12:865–874
  43. Seip R, Ebbini ES. Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound. IEEE Trans Biomed Eng. 1995;42:828–839
  44. Seip R, VanBaren P, Cain CA, Ebbini ES. Noninvasive real-time multipoint temperature control for ultrasound phased array treatments. IEEE Trans Ultrason Ferroelectr Freq Control. 1996;43:1063–1073
  45. Simon C, VanBaren P, Ebbini E. Two-dimensional temperature estimation using diagnostic ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control. 1998;45:1088–1099
  46. Straube WL, Arthur RM. Theoretical estimation of the temperature dependence of backscattered ultrasonic power for noninvasive thermometry. Ultrasound Med Biol. 1994;20:915–922
  47. Sun Z, Ying H. A multi-gate time-of-flight technique for estimation of temperature distribution in heated tissue: Theory and computer simulation. Ultrasonics. 1999;37:107–122
  48. Tao C, Du GH. Nonlinear transfer transform of energy in strongly focused finite-amplitude ultrasound. Acta Acustica Acustica. 2005;91:1031–1038
  49. Techavipoo U, Varghese T, Chen Q, Stiles TA, Zagzebski JA, Frank GR. Temperature dependence of ultrasonic propagation speed and attenuation in excised canine liver tissue measured using transmitted and reflected pulses. J Acoust Soc Am. 2004;115:2859–2865
  50. Willian HN. Modeling photocoagulation of the prostate during exposure to laser radiation. Doctor Dissertation. Vanderbilt University; 1996;
  51. Wilson WD. Speed of sound in distilled water as a function of temperature and pressure. J Acoust Soc Am. 1959;31:1967–1072
  52. Yoshizumi K, Sato T, Tchida N. A physicochemical evaluation of the nonlinear parameter B/A for media predominantly composed of water. J Acoust Soc Am. 1987;82:302–305
  53. Zhang D, Gong XF, Ye SG. Acoustic nonlinearity parameter tomography for biological spectrums via measurement of the second harmonic wave. J Acoust Soc Am. 1996;99:2397–2402
  54. Zhang D, Gong XF. Experimental investigation of the acoustic nonlinearity parameter tomography for excised pathological biological tissues. Ultrasound Med Biol. 1999;25:593–599
  55. Zhu Z, Roos MS, Cobb WN, Jensen K. Determination of the acoustic nonlinearity parameter B/A from phase measurement. J Acoust Soc Am. 1983;74:1518–1521

PII: S0301-5629(07)00467-X

doi: 10.1016/j.ultrasmedbio.2007.09.006

Ultrasound in Medicine and Biology
Volume 34, Issue 3 , Pages 414-424 , March 2008