Computer Aided Classification System for Breast Ultrasound Based on Breast Imaging Reporting and Data System (BI-RADS)

  • Wei-Chih Shen

      Affiliations

    • Department of Computer Science and Information Engineering, National Chung Cheng University, Chiayi, Taiwan, R.O.C.
  • ,
  • Ruey-Feng Chang

      Affiliations

    • Department of Computer Science and Information Engineering, National Chung Cheng University, Chiayi, Taiwan, R.O.C.
    • Department of Computer Science and Information Engineering, Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan, R.O.C.
    • Corresponding Author InformationAddress correspondence to: Professor Ruey-Feng Chang, Department of Computer Science and Information Engineering, National Taiwan University, Taipei, Taiwan 10617, R.O.C.
  • ,
  • Woo Kyung Moon

      Affiliations

    • Department of Radiology and Clinical Research Institute, Seoul National University Hospital, Seoul, Korea

Received 16 October 2006; received in revised form 7 May 2007; accepted 18 May 2007. published online 03 August 2007.

Abstract 

Clinically, the ultrasound findings are evaluated by its sonographic characteristics and then assigned to assessment categories according to the definitions of Breast Imaging Reporting and Data System (BI-RADS) developed by the American College of Radiology. In this study, a computer-aided classification (CAC) system was proposed to classify the masses into assessment categories 3, 4 and 5, which simulated the clinical diagnosis of radiologists. Compared with current computer-aided diagnosis systems, the proposed CAC system classifies the indeterminate cases into BI-RADS category 4 for further diagnosis. Six hundred twenty-six cases were collected from three ultrasound systems and confirmed by pathology and retrospectively classified into categories 3, 4 and 5 by radiologists. The multinomial logistic regression model was trained as the CAC system for predicting the assessment category from the computerized BI-RADS features and from a set of machine-dependent factors. By using the machine-dependent factors to indicate the adopted ultrasound systems, the same regression model could be applied for the cases acquired from different ultrasound systems. A basic CAC system was trained by using the classification result of radiologists. A weighted CAC system, to improve the capacity of the basic CAC system in differentiating benign from malignant lesions, was trained by adding the pathologic result. Between the radiologists and the basic CAC system, a substantial agreement was indicated by Cohen’s kappa statistic and the differences in either the performance indices or the AZ of receiver operating characteristic (ROC) analysis were not statistically significant. For the weighted CAC system, the performance indices accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 73.00% (457 of 626), 98.17% (215 of 219), 59.46% (242 of 407), 56.58% (215 of 380) and 98.37% (242 of 246), respectively; the AZ was 0.94; and the correlation with the radiologists was also substantial agreement. The indices accuracy and specificity of weighted CAC system, compared with those of the radiologists, were improved by 5.91% and 8.85%, respectively and the indices of sensitivity and NPV, compared with those of a conventional CAD system, were improved by 10.5% and 5.21%, respectively; all improvements were statistically significant. To classify the mass into BI-RADS assessment categories by the CAC system is feasible. Moreover, the proposed CAC system is flexible because it can be used to diagnose the cases acquired from different ultrasound systems. (E-mail: rfchang@csie.ntu.edu.tw)

Key Words: Breast cancer, Ultrasound image, BI-RADS, Computer-aided classification (CAC) system, Computer-aided diagnosis (CAD) system, Logistic regression

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(07)00260-8

doi:10.1016/j.ultrasmedbio.2007.05.016

Ultrasound in Medicine and Biology
Volume 33, Issue 11 , Pages 1688-1698, November 2007