Ultrasound in Medicine and Biology
Volume 33, Issue 11 , Pages 1767-1776, November 2007

Subharmonic Response of Encapsulated Microbubbles: Conditions for Existence and Amplification

Biomedical Engineering Department, Technion, Haifa, Israel

Received 14 September 2006; received in revised form 18 March 2007; accepted 12 May 2007. published online 28 August 2007.

Abstract 

The response of encapsulated microbubbles at half the ultrasound insonation frequency, termed subharmonic response, may have potential applications in diagnosis and therapy. The subharmonic signal, emitted by Definity microbubble cloud sonicated by ultrasound was studied theoretically and experimentally. The size distribution of the microbubbles was optically analyzed and resonance frequency of 2.7 MHz was determined. An asymptotic model has been developed that generates subharmonic response of a single and of a cloud of bubbles of various sizes. Threshold conditions for existence and the intensity of the subharmonic signal are predicted to depend on microbubbles size distribution and shell properties, as well as on the driving field frequency and pressure. Thin tubes filled with Definity solution were insonated at acoustic pressures from 100 to 630 kPa. The intensities of the emitted fundamental harmonics and subharmonics were measured. At frequency 5.5MHz, twice the resonance frequency, the subharmonic signals were observed only at pressures greater than 190 kPa. The subharmonic to fundamental harmonics intensity ratio was within −12 to −1 dB. The experimental results showed good correlation with the theoretical results in the range of validity of the asymptotic solution, thus supporting the model assumptions. (E-mail: agboris@tx.technion.ac.il)

Key Words: Microbubbles, Definity, Ultrasound, Subharmonic response, Subharmonic threshold

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(07)00255-4

doi:10.1016/j.ultrasmedbio.2007.05.011

Ultrasound in Medicine and Biology
Volume 33, Issue 11 , Pages 1767-1776, November 2007