Ultrasound in Medicine and Biology
Volume 33, Issue 8 , Pages 1191-1198, August 2007

High Frequency Ultrasound Assessment of Skin Fibrosis: Clinical Results

  • Y.P. Huang

      Affiliations

    • Department of Heath Technology and Informatics, Hong Kong Polytechnic University, Hong Kong, China
  • ,
  • Y.P. Zheng

      Affiliations

    • Department of Heath Technology and Informatics, Hong Kong Polytechnic University, Hong Kong, China
    • Corresponding Author InformationAddress correspondence to: Dr. Yongping Zheng, Department of Heath Technology and Informatics, Hong Kong Polytechnic University, Hong Kong, China.
  • ,
  • S.F. Leung

      Affiliations

    • Department of Clinical Oncology, Chinese University of Hong Kong, Hong Kong, China
  • ,
  • A.P.C. Choi

      Affiliations

    • Department of Heath Technology and Informatics, Hong Kong Polytechnic University, Hong Kong, China

Received 5 July 2006; received in revised form 24 January 2007; accepted 6 February 2007. published online 10 May 2007.

Abstract 

Fibrosis is a common late effect of radiotherapy treatment for cancer patients. Current clinical assessment of radiation-induced fibrosis is generally limited to clinician-based rating scales, which are usually not sufficient for quantitative and objective evaluations. Ultrasonic propagation properties of tissues are widely reported to be sensitive to the alterations of tissue compositions and structures. Based on our previous feasibility study, we used four parameters including skin thickness and three ultrasonic parameters of dermal tissues (attenuation slope [β], integrated attenuation [IA] and integrated backscatter [IBS]) in the frequency range of 10 to 25 MHz for the assessment of skin fibrosis. Experiments were conducted on the forearm and neck skin in patients with postirradiation fibrosis in the neck region. The palpation score and stiffness of the neck soft tissue were also measured as an indication of fibrotic severity. Comparisons of the results between 38 patients and 20 control subjects showed a significantly smaller β (p = 0.005) and a significantly larger skin thickness (p < 0.004) and IA (p = 0.04) in the neck skins of the patients. However, age-matched comparisons showed there were neither significant differences among patient subgroups with different fibrotic levels assessed using manual palpation or significant correlations between the four parameters and the overall stiffness of the neck soft tissues (p > 0.05). In conclusion, ultrasound tissue characterization may provide additional information for the assessment of postirradiation skin fibrosis in the neck region. Further studies are necessary to investigate the feasibility of applying the current measurement for differentiating the severity of skin fibrosis. (E-mail: ypzheng@ieee.org)

Key Words: Radiotherapy, Fibrosis, Skin, Soft tissue, Nasopharyngeal carcinoma (NPC), Attenuation, Backscatter, Hand palpation, Ultrasound indentation, Ultrasound

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(07)00106-8

doi:10.1016/j.ultrasmedbio.2007.02.009

Ultrasound in Medicine and Biology
Volume 33, Issue 8 , Pages 1191-1198, August 2007