Ultrasound in Medicine and Biology
Volume 33, Issue 6 , Pages 842-850, June 2007

The Kinematic Filling Efficiency Index of the Left Ventricle: Contrasting Normal vs. Diabetic Physiology

Cardiovascular Biophysics Laboratory, Cardiovascular Division, Washington University School of Medicine, St. Louis, MO, USA

Received 7 August 2006; received in revised form 18 October 2006 published online 10 May 2007.

Abstract 

An index of filling efficiency incorporating stiffness and relaxation (S&R) parameters has not been derived or validated, although numerous studies have focused on the effects of altered relaxation or stiffness on early rapid filling and diastolic function. Previous studies show that S&R parameters can be obtained from early rapid filling (Doppler E-wave) via kinematic modeling. E-wave contours are governed by harmonic oscillatory motion modeled via the parameterized diastolic filling (PDF) formalism. The previously validated model determines three (unique) oscillator parameters from each E-wave having established physiological analogues: xo (load), c (relaxation/viscoelasticity) and k (chamber stiffness). We define the dimensionless, filling-volume–based kinematic filling efficiency index (KFEI) as the ratio of the velocity-time integral (VTI) of the actual clinical E-wave contour fit via PDF to the VTI of the PDF model-predicted ideal E-wave contour having the same xo and k, but with no resistance to filling (c = 0). To validate the new index, Doppler E-waves from 36 patients with normal ventricular function, 17 diabetic and 19 well-matched non-diabetic controls, were analyzed. E-wave parameters xo, c and k and KFEI were computed for each patient and compared. In concordance with prior human and animal studies in which c differentiated between normal and diabetic hearts, KFEI differentiated (p < 0.001) between nondiabetics (55.8% ± 3.3%) and diabetics (49.1% ± 3.3%). Thus, the new index introduces and validates the concept of filling efficiency, and, using diabetes as a working example, provides quantitative and mechanistic insight into how S&R affect ventricular filling efficiency. (E-mail: sjk@wuphys.wustl.edu)

Key Words: Diastolic function, Doppler echocardiography, Efficiency, Diabetes, Optimal filling

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(06)01898-9

doi:10.1016/j.ultrasmedbio.2006.11.003

Ultrasound in Medicine and Biology
Volume 33, Issue 6 , Pages 842-850, June 2007