Myocardial blood flow measurements in rats with simple pulsing contrast echocardiography

  • Akira Oshita

      Affiliations

    • Kagawa Medical University School of Medicine, Kagawa, Japan
  • ,
  • Koji Ohmori

      Affiliations

    • Corresponding Author InformationAddress correspondence to: Koji Ohmori, M.D., Ph.D., Second Department of Internal Medicine, Kagawa Medical University, 1750-1, Ikenobe, Miki-cho, Kita-gun, Kagawa, Japan
    • Kagawa Medical University School of Medicine, Kagawa, Japan
  • ,
  • Yang Yu

      Affiliations

    • Kagawa Medical University School of Medicine, Kagawa, Japan
  • ,
  • Isao Kondo

      Affiliations

    • Kagawa Medical University School of Medicine, Kagawa, Japan
  • ,
  • Hiroto Takeuchi

      Affiliations

    • Kagawa Medical University School of Medicine, Kagawa, Japan
  • ,
  • Yuichiro Takagi

      Affiliations

    • Kagawa Medical University School of Medicine, Kagawa, Japan
  • ,
  • Yoshihiro Wada

      Affiliations

    • Kagawa Medical University School of Medicine, Kagawa, Japan
  • ,
  • Kazushi Yukiiri

      Affiliations

    • Kagawa Medical University School of Medicine, Kagawa, Japan
  • ,
  • Katsufumi Mizushige

      Affiliations

    • Kagawa Medical University School of Medicine, Kagawa, Japan
  • ,
  • Masakazu Kohno

      Affiliations

    • Kagawa Medical University School of Medicine, Kagawa, Japan

Received 16 August 2001; accepted 17 December 2001.

Abstract 

Relationship between contrast intensity and ultrasound (US) pulsing interval has been utilized to quantify myocardial blood flow (MBF) during myocardial contrast echocardiography (MCE). We tested if an MCE method employing a simple pulsing sequence during intravenous contrast infusion has the ability to quantify MBF in rats. We performed MCE in 17 rats using a 5- to 12-MHz broadband transducer during microbubble infusion via the femoral vein. Acoustic density (AD) from the anterior wall of the left ventricle imaged in the short axis plane was plotted against the frame number after shortening the pulsing interval (PI) from 1:20 to 1:1 end-systolic ECG gating. The relation between AD and frame number was fitted to a decay function. The rate of the AD decay was decreased during dipyridamole infusion, but was increased by causing coronary stenosis. The AD during long PI imaging remained unchanged during the interventions. Estimated MBF by MCE after correction by heart rate exhibited a close correlation (r = 0.83) with the present “gold standard” of colored microsphere-derived MBF. Thus, the decay rate of the contrast intensity obtained with the high-frequency transducer after abrupt shortening of PI during intravenous microbubble infusion may provide for noninvasive measurement of MBF in rats. (E-mail: komori@kms.ac.jp)

Keywords:  Ultrasound, Microbubble, Microsphere method, Myocardial blood volume, Dipyridamole

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(02)00481-7

Ultrasound in Medicine and Biology
Volume 28, Issue 4 , Pages 459-466, April 2002