Ultrasound in Medicine and Biology
Volume 27, Issue 10 , Pages 1319-1331, October 2001

Assessing spectral algorithms to predict atherosclerotic plaque composition with normalized and raw intravascular ultrasound data

  • Anuja Nair

      Affiliations

    • Department of Biomedical Engineering, ND20, Lerner Research Institute, The Cleveland Clinic Foundation, Cleveland, OH, USA
    • Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
  • ,
  • Barry D Kuban

      Affiliations

    • Department of Biomedical Engineering, ND20, Lerner Research Institute, The Cleveland Clinic Foundation, Cleveland, OH, USA
  • ,
  • Nancy Obuchowski

      Affiliations

    • Department of Biostatistics and Epidemiology, The Cleveland Clinic Foundation, Cleveland, OH, USA
  • ,
  • D.Geoffrey Vince

      Affiliations

    • Corresponding Author InformationAddress correspondence to: D. Geoffrey Vince, Ph.D., Department of Biomedical Engineering/ND20, The Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, Ohio 44195, USA
    • Department of Biomedical Engineering, ND20, Lerner Research Institute, The Cleveland Clinic Foundation, Cleveland, OH, USA

Received 14 August 2000; accepted 28 June 2001.

Abstract 

Spectral analysis of backscattered intravascular ultrasound (IVUS) data has demonstrated the ability to characterize plaque. We compared the ability of spectral parameters (e.g., slope, midband fit and y-intercept), computed via classic Fourier transform (CPSD), Welch power spectrum (WPSD) and autoregressive (MPSD) models, to classify plaque composition. Data were collected ex vivo from 32 human left anterior descending coronary arteries. Regions-of-interest (ROIs), selected from histology, comprised 64 collagen-rich, 24 fibrolipidic, 23 calcified and 37 calcified-necrotic regions. A novel quantitative method was used to correlate IVUS data with corresponding histologic sections. Periodograms of IVUS samples, identified for each ROI, were used to calculate spectral parameters. Statistical classification trees (CT) were computed with 75% of the data for plaque characterization. The remaining data were used to assess the accuracy of the CTs. The overall accuracies for normalized spectra with CPSD, WPSD and MPSD were, respectively, 84.7%, 85.6% and 81.1% (training data) and 54.1%, 64.9% and 37.8% (test data). These numbers were improved to 89.2%, 91.9% and 89.2% (training) and 62.2%, 73% and 59.5% (test) when the calcified and calcified-necrotic regions were combined for analysis. Most CTs misclassified a few fibrolipidic regions as collagen, which is histologically acceptable, and the unnormalized and normalized spectra results were similar. (E-mail: vince@bme.ri.ccf.org)

Keywords:  Intravascular ultrasound, Radiofrequency data, Spectral analysis, Tissue characterization, Histology correlation, Classification trees

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(01)00436-7

Ultrasound in Medicine and Biology
Volume 27, Issue 10 , Pages 1319-1331, October 2001