Ultrasound in Medicine and Biology
Volume 27, Issue 10 , Pages 1311-1317, October 2001

Real-time spatial compound imaging improves reproducibility in the evaluation of atherosclerotic carotid plaques

  • Steen Christian Kofoed

      Affiliations

    • Corresponding Author InformationAddress correspondence to: Dr Steen Christian Kofoed, Gentofte Hospital, Department of Vascular Surgery, DK-2900 Hellerup, Copenhagen, Denmark
    • Department of Vascular Surgery, Gentofte University Hospital, Hellerup, Denmark
  • ,
  • Marie-Louise Moes Grønholdt

      Affiliations

    • Department of Vascular Surgery, Rigshopitalet, Copenhagen University Hospital, Copenhagen, Denmark
  • ,
  • Jens E Wilhjelm

      Affiliations

    • Ørsted · DTU, Technical University of Denmark, Lyngby, Denmark
  • ,
  • Jean Bismuth

      Affiliations

    • Department of Vascular Surgery, Gentofte University Hospital, Hellerup, Denmark
  • ,
  • Henrik Sillesen

      Affiliations

    • Department of Vascular Surgery, Gentofte University Hospital, Hellerup, Denmark

Received 15 January 2001; accepted 28 June 2001.

Abstract 

Compound imaging has the ability of reducing speckle and clutter artifacts demonstrated in in vitro studies compared to conventional, single-angle imaging. We investigated intra- and interobserver agreement of 38 outlines of carotid artery plaque images acquired by these techniques, by measuring the overlapping area after repeated outlines. In general, both techniques showed good agreement. When considering the images with poorest overlap, compound imaging had a significant advantage over conventional imaging regarding both intra- and interobserver agreement. The interobserver variation for the overlapping area after two outlines was 20% for conventional technique and 10% for compound. The interobserver variation of the gray scale median value (GSM) for conventional technique ranged from −32 to +20 and from −6 to +6 for compound. Likewise, the coefficient of repeatability for the GSM value was 13 for conventional imaging and three for compound imaging, and interobserver variation for the GSM value for the overlapping area was 34% and 9% for conventional and compound technique. In conclusion, compound imaging improves intra- and interobserver agreement and reduces interobserver variation in the GSM value in a clinical setting. (E-mail: stko@gentoftehosp.kbhamt.dk)

Keywords:  Ultrasound, Compound imaging, Carotid artery, Plaque, Reproducibility

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0301-5629(01)00430-6

Ultrasound in Medicine and Biology
Volume 27, Issue 10 , Pages 1311-1317, October 2001