Ultrasound in Medicine and Biology
Volume 32, Issue 11 , Pages 1713-1720, November 2006

Model-based imaging

  • Armen Sarvazyan

      Affiliations

    • Corresponding Author InformationAddress correspondence to: Artann Laboratories, 1459 Lower Ferry Road, Trenton, NJ 08618-1414.

Artann Laboratories, Trenton, NJ, USA

Received 3 February 2006; received in revised form 11 May 2006; accepted 19 May 2006.

Abstract 

The concept of model-based imaging provides a possibility of integration of both structural and functional information obtained by imaging and nonimaging sources of diagnostically relevant information. Merging information of different origin and nature in a simulated computer patient-specific three-dimensional (3-D) model is important for multimodal imaging approaches to medical diagnostics. The work of F. L. Lizzi on life-like imaging done nearly 20 years ago was the first successful attempt of patient-specific 3-D computer modeling using conventional ultrasonography data. He demonstrated the applications of such 3-D models, which incorporated acoustic, optical and thermal properties of imaged tissue, in physiologic studies, in planning and monitoring ultrasonic hyperthermia and ablation. However, numerous obstacles hinder the wide use of the model-based imaging concept. Using the example of model-based imaging of prostate, the advantages and limitation on the applicability of the concept are discussed. Attempts of implementing the model-based imaging concept in the mechanical imaging technology—imaging with the use of measurements of stress pattern on the surface of tissue—are described. It is shown that composing a patient-specific 3-D model requires well-defined and carefully validated algorithms for translating features of the object assessed by an imaging modality into the quantitative anatomic and histopathologic parameters. (E-mail: armen@artannlabs.com)

Key Words: Patient-specific model, Multimodality imaging, Virtual reality, Knowledge-based imaging, Prostate imaging, Ultrasonography, Mechanical imaging

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 In memory of F. L. Lizzi.